Ultrasonic imaging-A novel way to investigatecorrosion status in post-tensioned concrete mambers
Abstract
The problem of durability in reinforced concrete structures in most prevalent in chloride-induced corrosion of reinforcing steel. Traditional corrosion monitoringg techniques such as half-cell potential and corrosion rate measurements often fail when used in this type of structure and standard nondestructive testing methods such as impact-echo have also encountered problems. This study introduces a new method called C-scan imaging to evaluate grouted post-tensioned tendons. Preliminary investigations on lab specimens show promise for the technique.
Keywords
Impact echo; ultrasound sensing; NDT (nondestructive testing); ultrasound bridge inspection system; wireless ultrasound C-scan imaging system.